213332

Onload Tap Changer Distribution Transformer

 

The performance of Farady SZ-M series SZ series 10KV and 35KV load ratio voltage transformer conform to the standard of GB 1094 and IEC 60076 ,the products are widely used in power transmission and distribution of indusrtrial and agricultural power networks ,because of the unstably of power supply.

Standard Feature
  1. Load-ratio voltage regulation, 
  2. high reliability, 
  3. advanced level of performances, 
  4. reasonable  economical  indictors
  5. The core joints are of stepped shape with 3 steps ,and the surface of the core is coated with cured  paint to lower loss and noise
Service Condition
  1. a) Suitable for indoor or outdoor application

b)Air temperature: Maximum temperature: +40; Minimum temperature:-30

  1. c) Humidity: Monthly average humidity 95%; Daily average humidity 90% .
  2. d) Altitude above sea level: Maximum installation altitude: 2000m.

e)Max wind speed:35M/s

  1. f) Ambient air not apparently polluted by corrosive and flammable gas, vapor etc.
  2. g) No frequent violent shake

Note: * Beyond those services condition should enquiry to manufacturer technical dept during order

Tests
  • Voltage ratio. Polarity and phase relationship test on each tapping
  • Resistance of all windings
  • No-load current and no-load losses measurement
  • Load losses measurement at rated current and frequency
  • Impedance voltage measurement
  • Induced over-voltage and separate source voltage withstand tests
  • Impulse voltage withstand test.
  • Noise level test
  • Oil leakage test
  • Overload test at 150% rated current for one hour after temperature rise test and hot resistance measurement of (HV – LV)
Specifications

Easy maintenance of diverter switch suitable upto 400 KV Class

Step voltage upto 4000 Volts

Current rating up to 2100 Amps

Linear 18 positions

Reversing and Coarse fine 35 Positions

PRS and Rupture disc can be provided simultaneously maintenance free dry lubricated spur gears of motor drive Low noise level

Tie-in-resistor for recovery voltage above 40 KV

Technical Specification

405

Operating Characteristics


 

Type

 

Voltage combination 

 

Vector group

Loss(W)

 

 

 

Impedance

 

%

 

 

Dimension

(L*W*H)

mm

 

 

Weight

(kg)

 

Primary

(KV)

 

Tapping range

 

Secondary

KV

No Load lossFull

load loss

SZ11-200 

 

6

6.3

6.6

10

10.5

11

13.2

13.8

15

 

 

 

 

 

 

±3×2.5%

±4×2.5%

±5×2.5%

 

 

 

 

 

 

0.4 or other

 

 

 

 

 

Yyn0 or

Dyn11

4303500 

 

 

 

 

 

4.0

1780*870*14501550
SZ11-25051041601940*880*15601600
SZ11-31561050101980*900*16101630
SZ11-40073060502050*1000*16502030
SZ11-50086072802100*1100*17002110
SZ11-630104082802190*1200*18002670
SZ11-800123099002200*1250*18802900
SZ11-10001440121502250*1280*19003400
SZ11-12501760146702300*1300*19804000
SZ11-16002120175502400*1390*20005500
SZ11-20002260179102490*1450*21006000
SZ11-25002680199502600*1490*22406500

Note: *The above parameter is only subject to our standard design, special requirement can be customized