General
Farady Electric strives to bring our customers the latest technology, competitive pricing, and the best service for pole-mounted Auto circuit reclosers.
The FAR series Auto circuit recloser is designed for overhead distribution lines and distribution substation applications across all voltage classes from 11kV up to 38kV at 50/60Hz power systems. The rated current can reach up to 1600A.
Service Condition
- Air temperature: Max +85℃; Min -45℃
- Monthly average humidity: 95%
- Daily average humidity: 90%
- Max installation altitude: 2500m or higher
- No corrosive/flammable gas or vapor pollution
- No frequent violent shake
Product Structure
| 1. ON/OFF Indicator | 2. Emergency Close | 3. Counter |
| 4. Manual OFF | 5. Earthing | 6. Secondary Socket |
| 7. Magnet Mechanism |
- High quality Solid Epoxy resin material
- Fully comply with ANSI std
- Guarantee 30,000 times operation
- Environment friendly, Oil / SF6 Gas free
- Suitable for both Pole mounted or Substation
- Reliable and Enhanced Life Expectancy
- Ambient temp: -40℃~80℃
| 1. Rogowski coil | 2. Voltage Sensor | 3. Vacuum Interrupter |
| 4. CT | 5. Conductor | 6. Push Rod |
| 7. Push Reed |
- High quality Vacuum Interrupter
- Voltage sensor Integrated
- CT Integrated
- Reliable Push rod
- Minimized moving components
- Maintenance free design
Controller
Voltlogic-351 series recloser controller is a medium voltage overhead line grid monitoring unit. Combined with vacuum circuit breakers, it achieves automatic reclose, measurement monitoring, fault analysis, and event recording. It supports wireless (GSM/GPRS/CDMA), Ethernet, WIFI, optical fiber, and RS232/485 communications.
| Protection functions | ANSI code | Name in Device |
| Phase overcurrent | 50P | P.OC |
| Overload | 49 | Overload |
| Phase Time-Overcurrent | 51P | P.Curve |
| Ground Overcurrent | 50G/N | E.F |
| Recloser | 79 | Reclose |
| Phase overcurrent cold load pick-up | CLPU 50 | Cold Load |
| Switch-Onto-Fault | - | SOTF |
| Undervoltage | 27 | Under volt |
| Overvoltage | 50P | P.OC |
- Phase current IA, IB, IC RMS, Zero Sequence
- Voltage Uab, Ubc, Uca, U0
- Active power, reactive power and power factor
- Frequency
- Circuit breaker control (ANSI 94)
- Latching / acknowledgement (ANSI 86)
- Flexible protection configuration switching
- 6 channels signal input / 4 channels current & voltage measure
- Large capacity flash memory (100+ historical events)
- Self-adaptation open/close brake function
- Complete self-inspection function
RS485, RS232, Ethernet. Protocols: IEC60870-5-101/104, IEC61850, Modbus RTU, DNP3.0