China Low Voltage Distribution Box (LVDB) - Suppliers & Factory for Outdoor/Indoor Applications

,
,
, , , , , , , , , , , , , , , , , , , , , , , ,
,

Model Series

,
,

LVDB

,
,

Rated Voltage 

,
,

400V

,
,

Standard

,
,

IEC 61439

,
,

Warranty

,
,

Two years

,
,

Application

,
,

Outdoor/Indoor

,
,
,
,
, , , , , , , , , , , , , , , , , , , , , , , ,
,

Model Series

,
,

CSS

,
,

Rated Voltage 

,
,

2.5~34.5kV

,
,

Standard

,
,

IEC 62271-202

,
,

Warranty

,
,

Two years

,
,

Application

,
,

Outdoor/Indoor

,
,
,
,

    With the strong assistance of our adept professionals, we are engrossed in supplying a large variety of Feeder Pillar Panel. The offered panel is Integrated with power distribution/metering/protection/control/reactive power compensation function.
    icon
    General
    This panel is extensively used in commercial and residential sectors for low voltage distribution applications. Before offering to the clients, this panel is stringently tested in order to ensure its flawless performance. Comply with standard IEC439.
    icon
    Service environment
    a) Air temperature: Maximum temperature: +40℃; Minimum temperature:-25℃.
    b) Humidity: Monthly average humidity 95%; Daily average humidity 90%.
    c) Altitude above sea level: Maximum installation altitude: 2500m.
    d) Ambient air not apparently polluted by corrosive and flammable gas, vapor etc.
    e) No frequent violent shake.
    icon
    Product feature
    Farady JP feeder pillar enclosure was made of 2mm high quality stainless steel plate after multiple bending flanging process (flame retardant, environmental protection, heat insulation, anti-condensation performance), using special stainless steel welding process, the overall strength after molding, the surface smooth as a mirror, do not leave weld marks; internal installation of beam (plate) for the hot galvanizing process, to ensure that the twenty years do not rust; the front and rear doors, easy operation and maintenance, the door was edged with high elastic aging sealant, each door is equipped with two types of lock, padlock with anti rain cover wall rust; whole closed with a sealing device measuring room; the side of the box is equipped with cable lines into the proof of foreign body wear tube, bottom ventilation holes and the cable outlet hole is arranged at the top of ventilation and screen, waterproof Anti rust, dustproof, anti-foreign object function, protection grade: IP54.
    icon
    Outdoor electrical distribution with advanced technology
    Farady low voltage, JP series Feeder Pillars use 304 stainless steel enclosure with IP54 protection degree suitable for outdoor use.
    icon
    Cost savings
    All weatherproof outdoor enclosures allow the equipment to be located in any outdoor environment, freeing up valuable indoor floor space whilst retaining remote operation and control.
    There are a wide range of metering instruments available for monitoring the unit locally or remotely, ensuring efficient operation.
    JP series Feeder pillars are available as part of a package substation with transformers and MV switch or circuit breakers. Additional cost savings are achieved through direct coupling from the transformer to the JP Feeder pillar eliminating expensive cable runs.
    icon
    Safety
    CCC certified, providing IP54 operator protection under all circumstances during operation, allowing electrical systems to be fully co-ordinated minimising electrical faults. In addition to the overload and short circuit protection, each breaker can be fitted with earth fault protection.
    icon
    Flexibility
    The modular design enables customisation for individual requirements, and has the flexibility to suit the changing needs of the LV distribution system.
    Maximum flexibility is achieved by the four pole busbar system up to 3200A and the Compact NS range of moulded circuit breakers of ratings up to 630A.
    As a complete unit, the JP Feeder Pillar will not only provide circuit protection, but the outgoing circuits can also be controlled individually via hardwired pilots or linked to the incoming breaker. Other "add-on" benefits include remote monitoring and status of each breaker and also remote operation through motor mechanisms.
    icon
    Easy installation
    The JP Feeder pillar comes complete and factory assembled for easy installation in any outdoor location with bottom entry cable through individual gland plates. The cable space is protected by an earthed metal screen, and each breaker is fitted with cable shrouds to maintain IP2X operator protection when the screen is removed.
    Addition of new circuits is made easy, by utilising the cassette on the MCCB breaker allows the breaker to be positioned anywhere on the busbar system before being clamped contributing minimum disruption of supply.
    icon
    Structure
    Outdoor Low Voltage Distribution Box (LVDB)01
    Outdoor Low Voltage Distribution Box (LVDB)02
    icon
    Installation size
    Outdoor Low Voltage Distribution Box (LVDB)03
    icon
    Ordering Instructions
    1. Below terms should be marked while ordering:
    ■ Incoming and outgoing
    ■ With reactive power compensation or not
    ■ Protection method(MCCM/ELCB or recloser)
    ■ Breaking capacity
    Frequently Asked Questions
    Q1: What functions are integrated into the Feeder Pillar Panel?
    The panel is integrated with power distribution, metering, protection, control, and reactive power compensation functions.
    Q2: What material is used for the enclosure?
    It is made of 2mm high-quality 304 stainless steel plate, featuring flame retardant, heat insulation, and anti-condensation properties.
    Q3: What is the protection grade of the JP series Feeder Pillar?
    The protection grade is IP54, making it highly resistant to dust, water, and foreign objects in outdoor environments.
    Q4: Can the system be monitored remotely?
    Yes, a wide range of metering instruments are available for both local and remote monitoring to ensure efficient operation.
    Q5: What certifications does the product hold?
    The product is CCC certified and complies with the IEC439 standard for low voltage distribution applications.
    Q6: Is it easy to add new circuits after installation?
    Yes, the modular design and MCCB cassette allow new breakers to be positioned anywhere on the busbar system with minimal disruption.

    Leave Your Message