Leave Your Message

LW3F Series 15KV/27KV/38KV SF6 Load Break Switch - Quality China Suppliers & Factory for Reliable Power Solutions

,
,
, , , , , , , , , , , , , , , , , , , , , , , ,
,

Model Series

,
,

LBS

,
,

Rated Voltage 

,
,

2.5–34.5kV

,
,

Standard

,
,

IEC 62271-1

,
,

Warranty

,
,

Two years

,
,

Application

,
,

Outdoor/Indoor

,
,

Introducing our top-tier LBS model series, designed for robust performance in both outdoor and indoor applications. With a rated voltage range of 2.5–34.5kV, this product meets the IEC 62271-1 standard, ensuring high reliability and safety. As a leading provider in China, we are proud to manufacture high-quality electrical solutions tailored to meet global standards. Our products come with a two-year warranty, assuring you of their durability and efficiency. Trust our factory to supply you with innovative and dependable electrical equipment, perfect for your needs.

,
,
,

    LW3F type pole-mounted SF6 load break switch was used in 12kV, 24kV, 33kV rated voltage, rated current 400/630A; 50/60HZ with the load current; over load current of power line open circuit and opening and closing electric systems.

    GeneralGeneral

    The switch can equipped with a controller with most advanced technical parameter.
    LW3F-A type: Manually LBS for choice.
    LW3F-M type: Intelligent type LBS for choice.
    It can automatically disconnect when the distribution line was break down.
    It could operated by handle; Implement electrification and distant. The electric controller was installed in stainless steel cabinet. So it could use in any conditions.
    LW3F series SF6 Load Break Switch

    Service ConditionService Condition

    Air temperature: Max +40℃; Min -20℃.
    Humidity: Monthly avg 95%; Daily avg 90%.
    Altitude: Maximum installation altitude 2500m.
    Environment: Ambient air not polluted by corrosive/flammable gas.
    Stability: No frequent violent shake.
    Service Condition Display

    Product StructureProduct Structure

    Product Structure Diagram
    Product Characters:
    High quality porcelain or Rubber bushing
    Full comply with IEC std
    Guarantee 4000 times operations
    Environment friendly
    Suitable for both Pole mounted or Hanging mounted
    Reliable and Enhanced Life Expectancy
    Ambient Temp: -40℃ ~ +80℃
    ① Operation Handle ② ON/OFF Indication ③ Installation Bracket
    ④ Operating Mechanism ⑤ Interrupter ⑥ Hanging Lug
    ⑦ Cable Bushing

    ControllerController

    1.1 Description
    Controller Unit
    Volt logic series line sectional load break controller is medium voltage overhead line grid monitoring unit. It can combined with load break switch for achieve of measure monitoring, fault analysis and event records. It supports Wireless (GSM/GPRS/CDMA), Ethernet mode, WIFI, optical fiber, and more.
    1.2 Protection functions
    Protection functions ANSI code Name in Device
    Phase overcurrent 50P P.OC
    Overload 49 Overload
    Phase Time-Overcurrent 51P P.Curve
    Ground Overcurrent 50G/N E.F
    Recloser 79 Reclose
    Undervoltage 27 Under volt
    Overvoltage 50P P.OC
    1.3 Metering & 1.4 Control
    Phase current IA, IB, IC RMS, Zero Sequency
    Voltage Uab, Ubc, Uca, U0
    Active/reactive power and power factor
    Switch control (94) & Lockout Relay (86)
    1.5 Features & 1.7 Communication
    13 channels digital signal input
    6 channels voltage measure
    RS485, RS232 port and Ethernet
    Protocols: IEC60870-5-101/104, Modbus RTU, DNP3.0
    1.8 HMI Software
    HMI Software Interface

    DimensionsDimensions

    15KV Dimensions

    15KV SF6 LOAD BREAK SWITCH

    24KV Dimensions

    24KV SF6 LOAD BREAK SWITCH

    36KV Dimensions

    36KV SF6 LOAD BREAK SWITCH

    InstallationInstallation

    Installation Guide

    FAQFrequently Asked Questions

    What is the rated voltage range for the LW3F load break switch?
    The LW3F series is designed for rated voltages of 12kV, 24kV, and 33kV.
    What is the difference between LW3F-A and LW3F-M models?
    The LW3F-A is a manually operated load break switch, while the LW3F-M is an intelligent type equipped with an advanced controller for automated operations.
    What communication protocols does the intelligent controller support?
    The controller supports multiple protocols including IEC60870-5-101, IEC60870-5-104, IEC61850, Modbus RTU, and DNP3.0.
    Can this switch operate in extreme weather conditions?
    Yes, it is designed for ambient temperatures ranging from -40℃ to +80℃ and is housed in a stainless steel cabinet for durability in various environments.
    What is the mechanical life expectancy of the switch?
    The product is guaranteed for 4000 operations, ensuring a reliable and enhanced life expectancy for distribution lines.
    What protection functions are integrated into the controller?
    It includes phase overcurrent (50P), overload (49), ground overcurrent (50G/N), recloser (79), and undervoltage (27) protections among others.

    Leave Your Message