MNS Series LV AC Withdrawable Switchgear: Top China Suppliers and Factory for Reliable Power Solutions
MNS LV withdrawable switchgear (hereinafter referred to as device) is manufactured by standard module and synthetically improved. The device is applicable to the system with AC 50Hz, rated working voltage 660V and below, used as control device for various power generation, transmission, distribution, power transfer and power consumption device.
General
MNS LV withdrawable switchgear (hereinafter referred to as device) is manufactured by standard module and synthetically improved. The device is applicable to the system with AC 50Hz, rated working voltage 660V and below, used as control device for various power generation, transmission, distribution, power transfer and power consumption device. It is widely used in low voltage distribution system of various mining enterprise, tall building and hotel, municipal construction etc. Besides the general land use, after special disposal, it also can be used for marine petrol drill taken platform and nuclear power station. The device accords with international standard IEC439-1.
Features
Compact design
Contain more function units with less space.
Strong versatility & Flexible assembly
C type bar section of 25mm modulus can meet the demands of various structure and type, protection grade and operating environment.
Standard module design
Can be combined into protection, operation, transfer, control, regulation, measurement, indication etc such standard units. User can choose assembly according to requirement at will. Cabinet structure and drawer unit can be formed with more than 200 components.
Fine security
Adopt high strength antiflaming type engineering plastic pack in large quantity to effectively enhance the protective safety performance.
High technical performance
Main parameters reach the advanced level at home.
Service environment
- Ambient air temperature: -5℃~+40℃ and the average temperature should not exceed +35℃ in 24h.
- Air condition: With clean air. Relative humidity should not exceed 50% at +40℃. Higher relative humidity is allowed at lower temperature. Ex. 90% at +20℃. But in view of the temperature change, it is possible that moderate dews will produce casually.
- Altitude: Altitude above sea level should not exceed 2000M.
- Transportation & Storage: The device is suitable to the transportation and store with following temperature: -25℃ ~+55℃, in short time (within 24h) it reaches +70℃. Under the limiting temperature, device should not suffer damage that can’t recover, and it can works normally under normal conditions.
- If the above operating conditions not meet user’s demand, consult with manufactory.
- Technical agreement should be signed additionally if the device is used for marine petrol drill taken platform and nuclear power station.
Structure Characteristics
The basic cabinet of device is combined assembly structure. Basic structural pieces of cabinet is zinc plated, connected and firmed into basic bracket through self tapping locking screw or 8.8 grade square corner screw. According to the change demand of project, additionally add corresponding gate, closing board, baffle plate, installation support and the components of bus bar, function units, to assemble a complete set of device. Perform modulus to interior component and compartment size (Modulus unit e=25mm).
Frequently Asked Questions (FAQ)
What is the application of the MNS LV withdrawable switchgear?
The device is applicable to systems with AC 50Hz, rated working voltage of 660V and below, used as a control device for various power generation, transmission, distribution, power transfer, and power consumption devices.
What are the key design features of this switchgear?
Key features include a compact design to contain more function units in less space, high versatility with a 25mm modular C-type bar section, standard module configuration, enhanced security with high-strength anti-flaming engineering plastics, and high technical performance.
What are the ambient temperature requirements for the service environment?
The ambient air temperature must be between -5℃ and +40℃, and the average temperature must not exceed +35℃ over a 24-hour period.
What are the humidity and altitude limits for installation?
Relative humidity should not exceed 50% at +40℃ (higher humidity like 90% is allowed at +20℃). The altitude above sea level should not exceed 2000 meters.
Can the device be used for marine platforms or nuclear power stations?
Yes, after special disposal, it can be used for marine petrol drill platforms and nuclear power stations. An additional technical agreement must be signed for these specific applications.
How is the cabinet structure assembled?
The basic cabinet utilizes a combined assembly structure. Zinc-plated basic structural pieces are connected and secured into a basic bracket using self-tapping locking screws or 8.8 grade square corner screws, adhering to an interior modulus unit of e=25mm.