SC(B)10 Series Three Phase Resin-Cast Dry-Type Distribution Transformer - China Suppliers and Factory Solutions
SC(B)10 series three phase resin-cast dry-type distribution transformer are in conformity with standard of IEC60076, with features of low loss, compact and light weight, low noise level, clamp-proof, anti-fouling, high mechanical strength, flame resisting.
General
Farady Electric manufacture a complete range of three phase distribution transformers, including oil-immersed type & cast resin dry-type transformer, we always designed with increased margins of safety and reliability, and meet the following standard:
IEC60076
IEEE Std
GB1094
Application
Strong overload ability and low partial discharge quality, they are application to power transmission and distribution system, hotel, restaurant, commercial building, stadiums, chemical plants, stations, airports, offshore drilling platforms, especially to heavy load centers and places with special fire protection requirements.
Mainly rating, types & capacity
Three phase
Two windings or three windings
On-load or no-load voltage tapping changer
Natural cooling or force air
10 - 2500kVA
Service condition
a) Suitable for indoor or outdoor application
b) Air temperature: Maximum temperature: +40℃; Minimum temperature: -30℃
c) Humidity: Monthly average humidity 95%; Daily average humidity 90%
d) Altitude above sea level: Maximum installation altitude: 2000m
e) Max wind speed: 35M/s
f) Ambient air not apparently polluted by corrosive and flammable gas, vapor etc.
g) No frequent violent shake
Note: * Beyond those services condition should enquiry to manufacturer technical dept during order
High reliability feature
Flame resistant
Explosion proof
Low temperature rise
Low loss & low noise
No environmental contamination
Frequently Asked Questions (FAQ)
What standards do SC(B)10 series transformers comply with?
SC(B)10 series resin-cast dry-type distribution transformers are engineered to conform with international IEC60076 standards, IEEE Std, and GB1094 standards.
What is the capacity range available for these dry-type transformers?
The capacity range spans from 10kVA to 2500kVA, configured with either two windings or three windings, and options for natural cooling (AN) or forced air cooling (AF).
Where are SC(B)10 dry-type distribution transformers typically applied?
They are ideal for power transmission systems, high-density load centers, and locations requiring high fire protection standards, such as commercial buildings, hotels, airports, chemical facilities, subways, and offshore drilling platforms.
What are the standard ambient operating conditions?
The units operate effectively within temperatures from -30℃ to +40℃, installation altitudes up to 2000m, monthly average humidity up to 95%, and maximum wind speeds of 35 m/s in environments free from corrosive or explosive vapor.
What are the main safety and environmental advantages of cast resin transformers?
Cast resin transformers eliminate liquid dielectric hazards, providing exceptional flame resistance, explosion-proof operation, low partial discharge, zero risk of oil contamination, and low operating noise.
Can these transformers be customized for special or extreme environments?
Yes. For operational demands beyond standard conditions (such as extreme altitudes, unusual temperatures, or harsh atmospheric conditions), custom engineering inquiries can be handled directly with Farady Electric's technical department.