Single Phase Overhead Distribution Pole Mounted Transformer from China Suppliers and Factory - D11 Model, 2.5-34.5kV

,
, , , , , , , , , , , , , , , , , , , , , , , , , , , ,
,

Model Series

,
,

D11

,
,

Rated Voltage 

,
,

2.5–34.5kV

,
,

Standard

,
,

 IEEE C57.12.20

,
,

Warranty

,
,

Two years

,
,

Application

,
,

Outdoor/Indoor

,
,

Manufacturer

,
,

Leading China Suppliers and Factory

,
,
,

    The Farady overhead transformer may be used alone for the supply of a single phase load or as one of three units in a bank for the supply of a three phase load.
    General IconGeneral
    The unit may be direct mounted to a wooden or concrete pole, or cluster mounted on a pole for three phase use. Our single phase overhead distribution transformer is commonly used in various places including rural areas, remote regions and scattered villages to provide high quality power supply for daily lighting, agricultural production and industrial plants. Aside from these, it is also suitable for the energy saving projects for railway and urban grid.
    Standards IconProduct Standards
    IEEE Std C57.12.00™-2000 standard – General Requirements for Liquid-Immersed Distribution, Power, and Regulating Transformers.
    IEEE Std C57.12.20™-2005 standard – Overhead-Type Distribution Transformers, 500kVA and Smaller.
    IEEE Std C57.12.31™-2010 standard – Pole Mounted Equipment – Enclosure Integrity.
    IEEE Std C57.12.35™-1996 standard – Bar Coding for Distribution Transformers.
    IEEE Std C57.12.90™-2006 standard – Test Code for Liquid-Immersed Distribution Transformers.
    IEEE Std C57.12.91™-2001 standard – Guide for Loading Mineral-Oil-Immersed Transformers.
    NEMA TR 1-1993 (R2000) Elevated Temperatures.
    (ASTM) American Society for Testing Materials
    Features IconMain Features
    Type: Conventional or CSP type
    Suitable for both indoor or outdoor
    Ambient temp: -25℃ to +40℃
    Winding temp rise: 55 ℃ or 65 ℃
    Core: CRGO or Amorphous Core
    Efficiency standard: DOE 2016 or NEMA TP1
    Winding material: CU or AL
    Frequency: 50HZ or 60HZ
    Capacity: 5kVA to 333kVA
    Quality IconQuality Assurance

    Farady Quality assurance is an integral part of the process. All electrical testing is per IEEE standards. Regular quality inspections and spot checking are conducted to maintain consistent quality.

    Routine Tests
    In-process Core Loss Test
    Transformer Turns Ratio Test
    Winding Resistance Test
    Polarity and Phase Displacement Test
    Insulation Power Factor Test
    Liquid Insulation DBV Test
    No Load Loss & Excitation Test
    Impedance Voltage & Load Loss Test
    Voltage Ratio Test
    Applied Potential Test
    Induced Potential Test
    Type Tests
    Temperature Rise Test
    Basic Impulse Level (BIL)
    Sound Level test
    Production IconProduction
    Frequently Asked Questions
    What is the capacity range of Farady single phase overhead transformers?
    The capacity ranges from 5kVA to 333kVA, suitable for various distribution needs.
    Can these transformers be used for three-phase power supply?
    Yes, while they are single-phase units, they can be cluster-mounted in a bank of three to provide a three-phase load supply.
    What core materials are available for these transformers?
    We offer both CRGO (Cold Rolled Grain Oriented) steel cores and Amorphous Cores for enhanced efficiency.
    Which standards do Farady overhead transformers comply with?
    They are designed and tested according to IEEE Std C57.12.00, C57.12.20, NEMA TR 1, and ASTM standards.
    What are the typical application areas for pole-mounted transformers?
    They are ideal for rural areas, remote regions, scattered villages, railway projects, and urban grid energy-saving upgrades.
    What winding materials are used in the construction?
    Customers can choose between Copper (CU) or Aluminum (AL) winding materials based on their specific requirements.