Leave Your Message

Single Phase Overhead Pole Mounted Transformer - D11 Model, China Factory Suppliers, Rated Voltage 2.5-34.5kV

,
, , , , , , , , , , , , , , , , , , , , , , , ,
,

Model Series

,
,

D11

,
,

Rated Voltage 

,
,

2.5~34.5kV

,
,

Standard

,
,

 IEEE C57.12.20

,
,

Warranty

,
,

Two years

,
,

Application

,
,

Outdoor/Indoor

,
,

Discover the exceptional D11 model series, a top-tier solution from leading China suppliers and factories. With a rated voltage of 2.5 to 34.5kV, our products meet the IEEE C57.12.20 standard, ensuring reliability and performance. Each unit comes with a two-year warranty, catering to both outdoor and indoor applications, making it an ideal choice for various installations. Trust in our quality and innovation as you partner with one of the most reputable manufacturers in China for your electrical needs.

,
,

    The Farady overhead transformer may be used alone for the supply of a single phase load or as one of three units in a bank for the supply of a three phase load.

    product-icoGeneral

    The unit may be direct mounted to a wooden or concrete pole, or cluster mounted on a pole for three phase use. Our single phase overhead distribution transformer is commonly used in various places including rural areas, remote regions and scattered villages to provide high quality power supply for daily lighting, agricultural production and industrial plants. Aside from these, it is also suitable for the energy saving projects for railway and urban grid.
    Single Phase Overhead Distribution Pole Mounted Tr01

    product-icoProduct Standards

    • IEEE Std C57.12.00™-2000 standard – IEEE Standard for Standard General Requirements for Liquid-Immersed Distribution, Power, and Regulating Transformers.
    • IEEE Std C57.12.20™-2005 standard – IEEE Standard for Overhead-Type Distribution Transformers, 500kVA and Smaller: High Voltage, 34500V and Below; Low Voltage, 7970/13800Y V and below.
    • IEEE Std C57.12.31™-2010 standard – IEEE Standard for Pole Mounted Equipment – Enclosure Integrity.
    • IEEE Std C57.12.35™-1996 standard – IEEE Standard for Bar Coding for Distribution Transformers.
    • IEEE Std C57.12.90™-2006 standard – IEEE Standard Test Code for Liquid-Immersed Distribution, Power, and Regulating Transformers.
    • IEEE Std C57.12.91™-2001 standard – IEEE Guide for Loading Mineral-Oil-Immersed Transformers.
    • NEMA TR 1-1993 (R2000) Elevated Temperatures.
    • (ASTM) American Society for Testing Materials

    product-icoMain Features

    Type & Installation
    Conventional or CSP type, suitable for both indoor or outdoor.
    Operating Temp
    Ambient temp: -25℃ to +40℃. Winding temp rise: 55 ℃ or 65 ℃.
    Core & Materials
    CRGO or Amorphous Core. Winding material: CU or AL.
    Specifications
    Capacity: 5kVA to 333kVA. Frequency: 50HZ or 60HZ. Efficiency standard: DOE 2016 or NEMA TP1.

    product-icoQuality Assurance

    Farady Quality assurance is an integral part of the process. All electrical testing is per IEEE standards. Quality of processed parts and subassemblies are the responsibility of the production personnel. Regular quality inspections and spot checking are conducted to make sure that good and consistent quality is achieved and maintained.
    Routine Tests
    • In-process Core Loss Test
    • Transformer Turns Ratio Test
    • Winding Resistance Test
    • Polarity and Phase Displacement Test
    • Insulation Power Factor Test
    • Liquid Insulation DBV Test
    • No Load Loss & Excitation Test
    • Impedance Voltage & Load Loss Test
    • Voltage Ratio Test
    • Applied Potential Test
    • Induced Potential Test
    Type Tests
    • Temperature Rise Test
    • Basic Impulse Level (BIL)
    • Sound Level test

    product-icoProduction

    Single Phase Overhead Distribution Pole Mounted Tr04
    Frequently Asked Questions

    What are the primary applications of the Farady single phase overhead distribution transformer?

    It is commonly used to provide high-quality power supply for daily lighting, agricultural production, and industrial plants in rural areas, remote regions, and scattered villages. It is also suitable for energy-saving projects for railway and urban grids.

    How can Farady overhead transformers be mounted?

    The unit can be direct mounted to a wooden or concrete pole, or cluster mounted on a pole for three-phase applications.

    What product standards do these overhead transformers comply with?

    They comply with several IEEE standards including IEEE Std C57.12.00™, C57.12.20™, C57.12.31™, C57.12.35™, C57.12.90™, C57.12.91™, and NEMA TR 1-1993 (R2000) standards.

    What capacity range is available for Farady overhead transformers?

    The capacity of these single-phase overhead distribution transformers ranges from 5kVA to 333kVA.

    What core materials and winding options are available?

    Farady overhead transformers are available with either CRGO or Amorphous Core, and can be built using Copper (CU) or Aluminum (AL) winding materials.

    What quality control tests are performed on these transformers?

    All electrical testing is performed per IEEE standards. This includes routine tests (like turns ratio, winding resistance, polarity, insulation power factor, no load loss, etc.) and type tests (such as temperature rise, basic impulse level, and sound level tests).