Model Series

S13

Rated Voltage

2.5~40.5kV

Industry Standards

IEC 60076-1 / EN 50588-1

Warranty Information

Two years

Application Areas

Outdoor/Indoor

This S13 model, made by reputable suppliers in China, is an exceptional solution for various applications requiring rated voltages from 2.5kV to 40.5kV. Complying with IEC 60076-1 and EN 50588-1 standards, this product promises reliability and safety for both indoor and outdoor use. We offer a two-year warranty, ensuring confidence in your purchase. Partner with our factory to experience unmatched quality and service in the electrical equipment industry.

    Farady offers a complete range of distribution transformers designed to grant the reliability, durability, and efficiency required in utility, industrial, and commercial applications.

    product-icoGeneral

    Farady's liquid-filled transformers are manufactured in accordance with the most demanding industry and international standards. Compliance with important standards, from IEC to VDE, is a matter of course, just as much as the exclusive use of high-quality materials, qualified employees implement the demanding standards in daily practice.
    Three Phase Oil Immersed Distribution Transformer02

    product-icoStandard Features

    1. Product Range: 15kVA-10000kVA, up to 44kV
    2. System voltage: max. 36 kVA 200 BIL
    3. Coolers: corrugated wall or radiator
    4. Oil preservation: hermetically sealed or conservator/free breathing
    5. Tap changer: off-circuit or on-load
    6. Cooling medium: mineral oil, Midel
    7. Steel type core clamping system
    8. High voltage (HV) multilayer winding
    9. Low voltage (LV) foil winding or layer winding
    10. Winding materials aluminium or copper
    11. High temperature class transformers
    12. Low noise solution
    13. Efficient transformers with reduced losses
    14. Liquid-filled
    15. Used in special conditions
    16. Sophisticated facilities
    17. Usage of wooden case
    18. 3D package for drawings
    19. Special test like Zero Sequence Impendence test
    20. Cooling: ONAN, ONAN/ONAF, KFAF, KFW

    product-icoService Condition

    a) Suitable for indoor or outdoor application.
    b) Air temperature: Maximum temperature: +40℃; Minimum temperature: -30℃.
    c) Humidity: Monthly average humidity 95%; Daily average humidity 90%.
    d) Altitude above sea level: Maximum installation altitude: 2000m
    e) Max wind speed: 35M/s
    f) Ambient air not apparently polluted by corrosive and flammable gas, vapor etc.
    g) No frequent violent shake.
    Note: * Beyond those services condition should enquiry to manufacturer technical dept during order.

    product-icoTests

    ●
    Voltage ratio. Polarity and phase relationship test on each tapping
    ●
    Resistance of all windings
    ●
    No-load current and no-load losses measurement
    ●
    Load losses measurement at rated current and frequency
    ●
    Impedance voltage measurement
    ●
    Induced over-voltage and separate source voltage withstand tests
    ●
    Impulse voltage withstand test
    ●
    Noise level test
    ●
    Oil leakage test
    ●
    Overload test at 150% rated current for one hour after temperature rise test and hot resistance measurement of (HV - LV)

    product-icoCustom Work- In Macrocosm And In Microcosm

    1. THE IRON CORE
    Whether in design, manufacturing methods or materials the cores of Farady transformers represent the latest state of technology. The silicon alloyed electric sheet steel used is grain-oriented, cold-rolled and insulated on both sides, guaranteeing low losses and noise and these values are even improved by laser treatment. Numerically controlled cutting machines provide for careful treatment in the cutting process in order to avoid mechanical tension in the core and thus unwanted properties right from the beginning. Standard use of step-lap cutting additionally minimizes losses and noise.
    Three Phase Oil Immersed Distribution Transformer03
    2. THE WINDING
    The winding as the centerpiece of the transformer must be especially protected -both against high electrical stress due to external over voltages and against mechanical overloads by short circuits. Farady transformers are systematically designed to meet these requirements. The windings are made of copper or aluminum. Low-voltage windings are made of strip or flat wire, and the high voltage windings are manufactured from round or profile wire. The use of insulating paper that is partially coated with epoxy resin ("diamond-dotted paper") bonds the winding into a compact block while drying and increases the short-circuit capacity additionally.
    Three Phase Oil Immersed Distribution Transformer04
    3. THE TANK
    Whether during transport or operation -the tank must be absolutely tight under mechanical stress. Preconditions to achieve this are constructional experience, the most modern calculation methods and high-quality welding work. Special attention is paid to corrosion protection. Pretreatment of the surface bysandblasting contributes to corrosion protection, just like multi coating with preset drying times for each layer. On request, hot-dip galvanization provides for even better protection. The tank must dissipate the entire heat loss of the transformer into the ambient air. This makes the volume of the transformer fluid change. In hermetically sealed transformers, the corrugated walls absorb the change in volume. In the case of expansion tank transformers, the conservator compensates this change. The sheet-steel lids of Farady transformers are bolted together with the tank or welded on request. In any case the steel thickness and the bracing is dimensioned in such a way that the lid withstands the stress of transport and operation.
    Three Phase Oil Immersed Distribution Transformer05
    Frequently Asked Questions (FAQ)
    What is the capacity range and voltage class of Farady distribution transformers?
    Farady offers distribution transformers ranging from 15kVA to 10000kVA, supporting system voltages up to 44kV (max. 36 kVA 200 BIL).
    What manufacturing standards do Farady liquid-filled transformers meet?
    The transformers are manufactured strictly according to international and industry standards, fully complying with both IEC and VDE requirements.
    What types of cooling systems and fluids are supported?
    They feature ONAN, ONAN/ONAF, KFAF, and KFW cooling methods utilizing mineral oil or Midel fluid, equipped with either corrugated walls or radiator panels.
    What are the standard ambient conditions for operating these transformers?
    The standard conditions include temperatures from -30℃ to +40℃, installation altitudes up to 2000m, monthly average humidity up to 95%, and max wind speeds of 35m/s.
    How does Farady ensure high short-circuit resistance and low core loss?
    Cores utilize laser-treated, grain-oriented cold-rolled silicon steel with step-lap cutting to minimize loss, while windings incorporate epoxy-coated diamond-dotted paper to form a rigid block against short-circuit forces.
    What quality and performance tests are executed prior to delivery?
    Routine and specialized tests include voltage ratio, winding resistance, load and no-load loss, impedance voltage, induced and impulse withstand, noise levels, oil leakage, and overload testing.

    Leave Your Message