Farady offers a complete range of distribution transformers designed to grant the reliability, durability, and efficiency required in utility, industrial, and commercial applications.
General
Farady's liquid-filled transformers are manufactured in accordance with the most demanding industry and international standards. Compliance with important standards, from IEC to VDE, is a matter of course, just as much as the exclusive use of high-quality materials, qualified employees implement the demanding standards in daily practice.
Standard Features
Product Range: 15kVA-10000kVA, up to 44kV
System voltage: max. 36 kVA 200 BIL
Coolers: corrugated wall or radiator
Oil preservation: hermetically sealed or conservator
Tap changer: off-circuit or on-load
Cooling medium: mineral oil, Midel
Steel type core clamping system
High voltage (HV) multilayer winding
Low voltage (LV) foil or layer winding
Winding materials: aluminium or copper
High temperature class transformers
Low noise solution
Efficient transformers with reduced losses
Liquid-filled technology
Used in special conditions
Sophisticated facilities
Usage of wooden case
3D package for drawings
Zero Sequence Impendence test
Cooling: ONAN, ONAN/ONAF, KFAF, KFW
Service Condition
a) Suitable for indoor or outdoor application.
b) Air temperature: Maximum +40℃; Minimum -30℃.
c) Humidity: Monthly average 95%; Daily average 90%.
d) Altitude above sea level: Max 2000m.
e) Max wind speed: 35M/s.
f) Ambient air not apparently polluted by corrosive/flammable gas.
g) No frequent violent shake.
Note: * Beyond those services condition should enquiry to manufacturer technical dept during order.
Tests
Voltage ratio, Polarity and phase relationship test
Resistance of all windings
No-load current and no-load losses measurement
Load losses measurement at rated current
Impedance voltage measurement
Induced over-voltage and separate source voltage tests
Impulse voltage withstand test
Noise level test
Oil leakage test
Overload test at 150% rated current for one hour
Custom Work- In Macrocosm And In Microcosm
1. THE IRON CORE
Whether in design, manufacturing methods or materials the cores of Farady transformers represent the latest state of technology. The silicon alloyed electric sheet steel used is grain-oriented, cold-rolled and insulated on both sides, guaranteeing low losses and noise and these values are even improved by laser treatment. Standard use of step-lap cutting additionally minimizes losses and noise.
2. THE WINDING
The winding as the centerpiece of the transformer must be especially protected against high electrical stress and mechanical overloads. Farady transformers are systematically designed to meet these requirements. The use of "diamond-dotted paper" bonds the winding into a compact block while drying and increases the short-circuit capacity additionally.
3. THE TANK
The tank must be absolutely tight under mechanical stress. Pretreatment of the surface by sandblasting contributes to corrosion protection, just like multi coating with preset drying times. In hermetically sealed transformers, the corrugated walls absorb the change in volume. The sheet-steel lids are bolted together with the tank or welded on request.
Frequently Asked Questions
Q1: What is the capacity range of Farady distribution transformers?
Farady offers a wide range from 15kVA up to 10000kVA, with system voltages reaching up to 44kV.
Q2: Which international standards do these transformers comply with?
Our transformers are manufactured in accordance with major international standards including IEC and VDE.
Q3: What materials are used for the transformer windings?
Windings are available in both aluminium and copper, depending on the specific application and customer requirements.
Q4: Are these transformers suitable for outdoor installation?
Yes, Farady distribution transformers are designed for both indoor and outdoor applications, featuring robust corrosion protection for the tank.
Q5: How does Farady ensure the low noise level of its transformers?
We use laser-treated grain-oriented silicon steel and step-lap cutting techniques in the iron core to significantly reduce noise and losses.
Q6: What cooling methods are supported?
We provide various cooling options including ONAN, ONAN/ONAF, KFAF, and KFW to meet different operational needs.